English  > EMC centers Introduction

EMC centers Introduction

Testing and Consulting

1.Measurements for standards (VCCI, FCC, EN, AS/NZS)

Registered laboratory of VCCI. Listed by FCC. The laboratories have been assessed and recognized in accordance with requirements ISO17025 by MEU Competent Body.
NARTE (The National Association of Radio & Telecommunications Engineers, Inc.) certified engineers and technicians assist your EMC design and control.

2. Conducted immunity test / Audible noise test (CISPR24, EN55024, etc.)

Audible noise instruments for conducted immunity test can be performed in connection with IT equipment as well as telecommuication terminal equipment.

3. Radiated immunity test up to 3GHz

The immunity test covers the frequency band for the next generation mobile phones and bluetooth/wireless devices.

4. Emission immunity test up to 3GHz

We realized the immunity test that covers the frequency band of the next generation mobile phones and bluetooth/wireless devices.

5. Near-field electromagnetic field measurement

We have the ESV-3000 that is capable of measuring near-field electromagnetic field intensity at 0.5 mm interval and shows the result as visual data. It is suitable for early-stage study in prototyping, along with EMC anechoic chamber.

6. Measurement of effectiveness of shielding materials

Both Centers can evaluate effectiveness of shielding based on MIL-STD-285.
This is optimal for characteristic evaluation, including shield materials and cabinet metals.

7. Consulting services

We provide consulting and countermeasures design support services to assist you to acquire CE marking and other international standards.

8. Total solution service

In addition to EMC, we provides total solution service of electronics, including vibration/shock resistance and heat resistance.

Major Equipment

 

Kasugai EMC Center

 

Registered laboratory of VCCI and FCC
Anechoic chamber (3 meter mehthod)
(150kHz - 18GHz)
Shield room

Measurement site

Shield room: 4×7×h 3m、100dB+

Measurement room: 3×7×3m、80dB+

Power source (Same for all rooms)
DC:0 - 60V (40A), - 120V (22A)
AC:1V - 135V (50/60Hz,22A,single phase)
AC:135V - 270V (50/60Hz,11A,single phase)
AC:200V, 230V(60Hz,20A,single phase/3-phase)

Emission measurement

EMI receiver 9kHz - 3GHz

Spectrum analyzer 9kHz - 22GHz

Preamplifier 10MHz~27GHz

Artificial mains network
Impedance stabilization network for telecommunication port.
Mains harmonic analyzer
Voltage variation/flicker tester

Immunity measurement

Standard signal generator 10MHz - 20GHz

Power amplifier 80MHz - 1GHz: 100W, 1GHz - 4GHz: 50W

Fast transient/burst tester
Electrostatic tester
Power sensor/meter
Lightning surge tester
Field intensity meter
Power frequency magnetic field
immunity tester

Others

Absorbing clamp / Platform
Antennas
(dipole, monopole, monopole, biconical, log periodic, bilog, horn)
Offices for customers (2)

Price

Please use "Contact" on the top page of our Product site.
We prepare special offers, including yearly contract.

Pick Up

Products & Service Contact

Please request brochures and samples by contact page on "All Products Listing Site".   Questions are also accepted by Q&A page on "All Products Listing Site".

Inquiry form

PAGE TOP